Multiplexor Divisionis Longitudinis Undae FTTH Triplex 1310 1490 1550nm Fibra Optica FWDM SC/UPC SC/APC
Specificationes
| Typus | FWDM | |
| Longitudo Undae Operativae T: longitudo undae transmissionis R: longitudo undae reflexionis 1310±50, 1490±10, 1550±10 1610±10, 1625±25, 1650±20 | nm | T1550 R1310/1490 |
| T1490 R1310/1550 | ||
| T1310 R1490/1550 | ||
| T1550/1610 R1310/1490 | ||
| T1550/1625 R1310/1490 | ||
| T1625 R1310/1490/1550 | ||
| T1650 R1310/1490/1550 | ||
| Damnum insertionis transmissionis | dB | ≤0.80 |
| Damnum insertionis reflexionis | dB | ≤0.60 |
| Isolatio canalis transmissionis | dB | ≥30 |
| Isolatio canalis reflexionis | dB | ≥17 |
| PDL | dB | ≤0.1 |
| Stabilitas thermalis longitudinis undae | nm/℃ | ≤0.003 |
| Stabilitas thermalis amissionis insertionis | dB/℃ | ≤0.005 |
| Directivitas | dB | ≥55 |
| Damnum reditus | dB | ≥45 |
| Temperatura operandi | Celsius | -20~+70 |
| Temperatura repositionis | Celsius | -40~+85 |
Nota: 1. Adaptabilitas praesto est.
2. Sine connectore specificatum, et addita iactura 0.2dB per connectorem.
Descriptio Producti
•Multiplexor Divisionis Longitudinis Undae per Filtrum Fibrae Opticae (FWDM) in technologia filtri pelliculae tenuis stabilis erga ambitum fundatur.
•Haec instrumenta lucem diversarum longitudinum undarum in lato ambitu longitudinum undarum coniungunt vel separant.
•Iacturam insertionis minimam, dependentiam polarizationis humilem, isolationem magnam, et stabilitatem environmentalem excellentem offerunt. Magna facultas potentiae tractandae per singularem processum pigtail et obductionem AR altae qualitatis obtineri potest.
•Hae partes late in EDFA, amplificatoribus Raman, retibus WDM et instrumentis fibrae opticae adhibitae sunt.
•Multiplexator Divisionis Longitudinis Undae Filtri (FWDM), FWDM T1550 R1310 et 1490 multiplexationem et demultiplexationem signorum opticorum duorum canalium 1550/1310 et 1490 consequi potest.
•Multiplicator capacitatis transmissionis fibrae opticae singularis fabricatus, late adhibitus in melioratione retium fibrae opticae et CATV etc.
•Instrumentum habet iacturam insertionis humilem, viam opticam sine resina epoxy, rationem extinctionis altam, magnam firmitatem et stabilitatem.
•Modus sarcinae: Tubus ferreus, arca modularis nigra ABS.
•Fibra optica nuda, funiculus input/output 0.9 mm, 2.0 mm, et 3.0 mm.
•Fibra optica nuda, funiculus input/output 0.9 mm, 2.0 mm, et 3.0 mm.
Applicationes
- HFC (reticulum fibrae et coaxialis pro CATV, CCTV)
- Omnes applicationes FTTH.
- Systema retis fibrae opticae passivae.
Proprietates
•Technicae fabricationis FBT probatae
•Efficacia latae fasciae
•Stabilis in ambitu
•Polarizationis insensibilis
•Involucrum miniaturizatum vel robustum
•Conectores et funiculi ordinarii praesto sunt.
•Technologia fusa productum.
•Damnum Insertionis Humile (IL)
•Alta isolatio-
•Damnum Dependens a Polarizatione Humili (PDL)
•Filtrum WDM portus 1x2 cum designo compacto
•Lata amplitudo longitudinis undae operativae
•Alta fides et alta stabilitas
Magnitudo tubi ferrei FWDM:
Modus sarcinandi FWDM: