KCO-Fiver-MTP-MPO-QSFP-Vexillum-pagina-1

SFP+/QSFP

SFP contra QSFP
SFP QSFP
Transceptor SFP (Small Form-factor Pluggable) uno canali utitur ad transmittenda et recipienda data. QSFP (Quad Small Form-factor Pluggable) quattuor canales in unum modulum coniungit ut quadruplam latitudinem transmissionis assequatur.
SFP (1 Lane): Parvam superficiem habet cum unica lane ad transmittendum (Tx) et recipiendum (Rx). Consuete utitur connectoribus LC duplex vel SC simplex. QSFP (Quattuor Viae): Latius spatium habet. Quattuor canales transmissionis et quattuor canales receptionis independentes continet. Typice utitur connectoribus MPO/MTP altae densitatis (pro opticis parallelis) vel multiplexatore interno super LC duplex (pro Multiplexatione Divisionis Longitudinis Undae).
Factor Formae Rates Datarum Primariae Communis Norma / Typi Usus Typici Casus
SFP 1 Gbps SFP 1G Nexus societatum hereditariarum
SFP+ Decem Gigabytes per secundum 10G SFP+ Nuclei societatum modernarum
SFP28 25 Gbps 25G SFP28 5G FTTA / Centra datorum
SFP56 50 Gbps 50G SFP56 Mediae viae sine filo, computatio specializata
QSFP+ 40 Gbps (4 x 10G) 40G Basis-SR4 / LR4 Strata distributionis societatum
QSFP28 100 Gbps (4 x 25G) 100G Basis-SR4 / LR4 Telae foliorum-spinarum centri datorum
QSFP56 200 Gbps (4 x 50G) 200G FR4 / DR4 Greges intellegentiae artificialis et infrastructura nubis
KCO QSFP+ 40G SR4 40Gb/s QSFP+ MMF 100M MPO Connector Transceptor cum DDM

KCO QSFP+ 40G SR4 40Gb/s QSFP+ MMF 100M MPO Connector Transceptor cum DDM

Capacitas Canalis Alta: 40 Gbps per modulum

Usque ad 11.1 Gbps celeritas datorum per canalem

Maxima longitudo nexus 100m in fibra multimodali OM3 vel 150m in fibra multimodali OM4.

Technologia VCSEL 850nm altae firmitatis

Electrice calide inseribilis

Diagnostica digitalis SFF-8436 congruens

Temperatura operationis capsulae: 0°C ad 70°C

Dissipatio potentiae < 0.7 W

KCO QSFP28 100G ER4 ER4L-S SMF 1310nm 40km WDM LC 100Gb/s QSFP28 ER4 SMF 1310nm WDM DLC Transceptor Opticus

KCO QSFP28 100G ER4 ER4L-S SMF 1310nm 40km WDM LC 100Gb/s QSFP28 ER4 SMF 1310nm WDM DLC Transceptor Opticus

+ Transceptor fibrae opticae KCO QSFP28 100G ER4 iter receptoris et transmissoris in uno modulo integrat. In latere transmissionis, quattuor viae fluminum datorum serialium recuperantur, tempora denuo disponuntur, et ad quattuor impulsores laser traduntur.

+ Rectores laserici 4-EML cum longitudine undae centrali 1296 nm, 1300nm, 1305nm et 1309 nm gubernant.

KCO QSFP28 100G LR4 SMF 1310 10km DOM LC 100Gb/s QSFP28 Transceptor Fibrae LR4 Modi Singularis

KCO QSFP28 100G LR4 SMF 1310 10km DOM LC 100Gb/s QSFP28 Transceptor Fibrae LR4 Modi Singularis

KCO QSFP28 100G LR4Transmissor opticus viam receptoris et transmissoris in uno modulo integrat. In latere transmissionis, quattuor viae fluminum datorum serialium recuperantur, tempora denuo disponuntur, et ad quattuor impulsores laser traduntur.

Rectores laser quattuor laseres cum retroactione distributa (DFB) gubernant, quorum longitudines undae centrales sunt 1296 nm, 1300 nm, 1305 nm, et 1309 nm. Signa optica per connectorem LC secundum normam industrialem ad fibram unius modi multiplexantur.

Transceptor Fibrae Opticae 100G QSFP28 PSM4 SMF 1310nm 2KM MTP MPO

Transceptor Fibrae Opticae 100G QSFP28 PSM4 SMF 1310nm 2KM MTP MPO

- P/N:KCO-QSFP28-100G-PSM4

- Usque ad 26Gbps per canalem latitudo transmissionis;

- Conforme cum QSFP28 MSA

- Canales quattuor 1310nm DFP

- Series detectorum photo-PIN quattuor canalum

- Usque ad 2 km per fibram monomodalem ordinariam extenduntur

- Coniunctori MTP MPO compatibilis

- Interfacies electrica calida inserenda

- Singula +3.3V fons potentiae operans

- Temperaturae commerciales a 0°C ad 70°C

- Conforme IEEE 802.3ba pro nexibus 100GBASE-PSM4

- Pars RoHS congruens

KCO QSFP28 100G ZR4 SMF 1310nm 80km WDM LC Fibrae Opticae Transceptor

KCO QSFP28 100G ZR4 SMF 1310nm 80km WDM LC Fibrae Opticae Transceptor

KCO QSFP28 100G ZR4 ad applicationes communicationis opticae 80km destinatur.

Hic modulus continet transmittorem opticum quattuor viarum, receptorem opticum quattuor viarum, et blocum administrationis moduli cum interfacie seriali duorum filorum.

Signa optica per connectorem LC normae industrialis ad fibram monomodalem multiplexantur.

Modulus Transceptoris Optici LC/UPC MMF Duplex 100GBASE-SR SWDM4 QSFP28 BiDi 850/880/910/940nm 100m DOM Compatibilis Cisco

Modulus Transceptoris Optici LC/UPC MMF Duplex 100GBASE-SR SWDM4 QSFP28 BiDi 850/880/910/940nm 100m DOM Compatibilis Cisco

KCO QSFP28100G SRBD MMF 100M LC Duplex DOM

Modulus Transceptoris Optici Bidirectionalis 100GBASE-SR SWDM4 QSFP28 Compatibilis cum Cisco pro Ethernet et Centro Datorum (MMF, 850/880/910/940nm, 100m, LC, DOM)

Modulus Transceptoris Optici Cisco Compatibilis 100GBASE-SR4 QSFP28 850nm 100m DOM MPO-12/UPC MMF, Breakout ad 4 x 25G-SR cum DDM

Modulus Transceptoris Optici Cisco Compatibilis 100GBASE-SR4 QSFP28 850nm 100m DOM MPO-12/UPC MMF, Breakout ad 4 x 25G-SR cum DDM

Usque ad 27.952 Gbps celeritas datorum per canalem

Maxima longitudo nexus 150m in fibra multimodali OM4

Technologia VCSEL 850nm altae firmitatis

Electrice calide inseribilis

Diagnostica digitalis SFF-8636 congruens

Congruens cum QSFP28 MSA

Temperatura operationis capsulae: 0°C ad 70°C

Dissipatio potentiae < 2.0W

KCO QSFP56 200G FR4 S SMF 2km DLC QSFP56 Transceptor Fibrae Opticae 200G-FR4H OSFP SMF Duplex LC 2km

KCO QSFP56 200G FR4 S SMF 2km DLC QSFP56 Transceptor Fibrae Opticae 200G-FR4H OSFP SMF Duplex LC 2km

- Usque ad 50Gbps celeritas datorum per canalem per modulationem PAM4

- Quattuor canales duplex transmissores et receptores

- Integrata CWDM LD et PD series

- Interfaciei connexionis Duplex LC/UPC congruenti

- Singula +3.3V fons potentiae 6, functio DDM implementata

- Forma QSFP56 calide inserenda

- Maxima longitudo nexus 2km per fibram SMF

- Dissipatione potentiae humili: <6.5W

- Classis 1 internationalis securitatis lasericae certificata

- Temperaturae operandi ambitus: 0Celsius~ +70Celsius

- ROHS congruens

KCO QSFP56 200G LR4 S SMF 1310nm 10km DOM DLC 200GBASE-LR4 QSFP56 1310nm 10km DOM Duplex LC SMF Transceptores Fibrae Opticae

KCO QSFP56 200G LR4 S SMF 1310nm 10km DOM DLC 200GBASE-LR4 QSFP56 1310nm 10km DOM Duplex LC SMF Transceptores Fibrae Opticae

- 200GBASE-LR4 congruens, 4x 26.5625 GBd PAM4

- 200GAUI-4 congruens, 4x 26.5625 GBd PAM4

- Forma QSFP56 calide inserenda

- QSFP+ 28 Gb/s congruens

- Maxima longitudo nexus decem chiliometrorum per SMF

- Conector LC duplex

- Dissipatione potentiae humili: <8.0W

- Temperatura operandi: 0 ad 70ºC

KCO QSFP56 200G SR4 S MMF MPO-12 100m 200Gbps QSFP56 OSFP Multimodus 100m MTP MPO Transceptor Fibrae Opticae

KCO QSFP56 200G SR4 S MMF MPO-12 100m 200Gbps QSFP56 OSFP Multimodus 100m MTP MPO Transceptor Fibrae Opticae

- Transceptor QSFP56 calidus inserendus

- Rationem transmissionis aggregatam 212,5 Gbps sustinet

- Usque ad 53.125Gbps celeritatem datorum per canalem

- Portus QSFP56 SFF-8665 congruens;

- Administratio I2C cum SFF-8636 conformis

- Conforme cum IEEE802.3cd 200GBASE-SR4

- Receptaculum connectoris MPO-12 cum superficie terminali UPC

- Maxima longitudo nexus 100m in OM4 MMF

- Singularis fons potentiae 3.3V

- Dissipatione potentiae humili (<4.5W)

- Temperaturae in capsula operativa: 0°C ad 70°C

- RoHS congruens

KCO-QDD-400G-SR8-S MMF 850nm 100m DOM MPO-16/APC

KCO-QDD-400G-SR8-S MMF 850nm 100m DOM MPO-16/APC

Modulus Transceptoris Optici 400GBASE-SR8 QSFP-DD Compatibilis, Coniunctus cum 2 × 200G-SR4 et 8 × 50G-S.

- Forma QSFP-DD calide inserenda

- Rationem transmissionis aggregatam 400Gb/s sustinet

- Usque ad 53.125Gbps celeritatem datorum per canalem

- Maxima longitudo nexus 70m in OM3 et 100m in OM4

- Receptaculum connectoris MPO

- Temperaturae capsulae: 0 ~ +70Celsius

- Dissipatione potentiae: <10W

- Singularis fons potentiae 3.3V

- Compatibilitas in retibus Arista/NVIDIA/Cisco RoCE probata

- Alta Latitudo Frequentiae

- Latentia Humilis

- Conforme QSFP-DD MSA

- Conforme cum IEEE 802.3cd

- Querela RoHS

KCO QDD 400G FR S 4*100G PAM4 SMF 1310nm 2KM MPO-12 QDD-4x100G-FR-S

KCO QDD 400G FR S 4*100G PAM4 SMF 1310nm 2KM MPO-12 QDD-4x100G-FR-S

Modulus Transceptoris Optici PAM4 400GBASE-FR QSFP-DD 4*100G compatibilis, apparatus fibrae opticae DOM MPO-12/APC 1310nm 2Km

- QSFP-DD MSA congruens

- Coniunctor MPO-12 cum superficie terminali angulata 8°

- Consumptio potentiae <11 W

- Temperatura capsulae operativae 0 ad 70°C

- Interfacies administrationis CMIS 4.0

- Modus Eruptionis • 4x 100GBASE-FR1 congruens 53.125GBd PAM4 • 100GAUI-2 congruens 2x 26.5625 GBd PAM4

- Modus Aggregationis • 400GBASE-FR4 congruens 4x 53.125GBd PAM4 • 400GAUI-8 congruens 8x 26.5625 GBd PAM4

Usus SFP et QSFP in solutionibus FTTH et FTTA

Metrica Designandi FTTH (Fibra ad Domum) FTTA (Fibra ad Antennam)
Modulus Marginis (SFP) GPON / XGS-PON SFP (Simplex SC) 25G SFP28 eCPRI (LC Duplex vel BiDi)
Modulus Centralis (QSFP) Nexus Ascendentes Retiales QSFP28 / QSFP-DD Eruptiones Radiophonicae QSFP28 a Portu ad SFP28
Protocollum Primum Strata Ethernet / ATM CPRI (4G) / eCPRI (5G in Fasciculis)
Requisitum Temperationis Commercialis (0°C ad 70°C) intra CO2 Industrialis (-40°C ad 85°C) ad malum ascendens
Usus [ OLT Officii Centralis ] ===( Nexus Ascendens QSFP )===> [ Commutatio Centralis ]
|
(PON SFP)
|
[ Passive Splitter ] --> [ Home ONT / ONU ]
[ Centrum BBU / DU ] ===( Eruptio QSFP28 )===> [ Quattuor Portus Turris SFP28 ]
||
(Trucbus Verticalis)
||
[25G SFP28 RRU]
Retia FTTH magnopere nituntur topologiis Retium Opticarum Passivarum (PON) ad distribuendum interrete ab Officio Centrali (CO) ad singulas domos. Norma SFP28 (25G): Cellulae macro 5G modernae in transceptoribus SFP28 25G specialiter pro protocollis eCPRI (Enhanced Common Public Radio Interface) constructis currunt.
Latus OLT: Chassis Terminalis Lineae Opticae (OLT) modulos SFP PON speciales (GPON, XGS-PON, vel 25G-PON) utuntur. Hi moduli SFP simplex BiDi (bidirectionales) sunt—uno connectore SC utentes ad transmittendum in una longitudine undae (e.g., 1490nm) et recipiendum in alia (e.g., 1310nm) ad serviendum usque ad 32 vel 64 domos per unum filum fibrae. Durabilitas Industrialis: SFTs in turrim dispositae temperaturae industrialis (-40°C ad 85°C) aptatae esse debent ut tempestatibus extremis secundum tempus anni superent. In robustas capsas externas, ut FullAXS vel ODVA, integrantur antequam directe in Unitatem Radiophonicam Remotam (RRU) inserantur.
Latus ONT/ONU: Terminus retiaculi optici a latere clientis intra domum vel negotium saepe modulos 1G SFP vel 10G SFP+ ordinarios in portam residentialem insertos adhibet. BiDi et CWDM: Ad pondus et opes fibrae in turri conservandas, technici saepe modulos BiDi SFP28 vel CWDM SFP28 utuntur, quod permittit ut plures fasciae frequentiae pauciores fila vitrea communicent.
Usus QSFP (Nucleus Officii Centralis): Usoribus domesticis moduli QSFP non utuntur. Potius, transceptores QSFP28 (100G) vel QSFP-DD (400G/800G) intra Officium Centrale adhibentur. Ingentem commeatum coniunctum ex multis chartis linearibus PON SFP aggregant et eum sursum ad nucleum interretiale latiorem dirigunt. Distributiones Breakout: Loco 24 funium SFP singularium, encaminator altae densitatis baseband portus QSFP28 (100G) in modo breakout utetur. Portus singularis QSFP28 funiculo truncali MPO breakout 1-ad-4 assignatur, quattuor canales eCPRI 25G independentes directe ad quattuor radios turris separatas efficaciter tradens.

Processus
Processus
Processus